This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Koster Injection Gel G4
Koster Injection Gel 4 is a low viscosity acrylic gel for curtain injection and injection into masonry.
Suitable for waterproofing belowground construction elements on the outside by curtain injection. For injection into full brick masonry in order to seal the mortar joints against water ingress. Can be applied in special waterproofing projects, like tunnels, shafts and void injections.
This water based, elastic acrylic gel has a very low starting viscosity after initial mixing. It is capable to bind water during the gelation. The swelling ability after full curing allows a 10% intake of additional water into the gel structure. Due to the low starting viscosity it can be injected into fine substrate pores.
Koster Injection Gel G4 is injected using a 2-component-injection pump with an integrated water flush, e. g. the Koster Acrylic Gel Pump. Before application the delivered concentrate needs to be diluted to approximately the double amount using local tap water.
Enquire about this product
- Application
- Product Details
- Downloads
- Technical Drawings
- Low viscosity acrylic gel for curtain injection and injection into masonry
- Highly elastic
- Can be injected into fine substrate pores
- Easy application
- Seamless application
- Fast curing
- Drinking water certification
- Capable of binding water during gelation
- Swelling ability after full curing allows a 10% uptake of additional water into the gel structure
- Suitable for new construction and repair on existing structures
This unique injection gel ready mixed components have a pot life of 24 hours.
Always wear protective clothing, gloves and safety goggles during the processing and application of Koster Injection Gel G4.
When installing do not stand directly behind the packer.
Clean the pump/machinery immediately after use with clean water.
Suitable for waterproofing basements